Forum Replies Created
-
AuthorPosts
-
Thanks for this one. I didn’t think of the URL mismatch – I had a typo that was hard to spot but your most made me take a closer look.
December 17, 2008 at 1:20 PM in reply to: a listen with an activatable receive cannot have a timeout #21415I have a parallel Action with multiple recieve shapes for msgs I am subscribing to. i need to get all 4 messages within an hour or send an error message.
So I put listen shapes within the parallel convoy with delay shapes set to an hour delay.
Do you know how to accomplish this otherwise?
Thank You.
December 17, 2008 at 9:37 AM in reply to: How could I generate schema using COVAST EDI Accelerator #21414covast will give schema files…u just need to import into Covast Accelerator….
the answer’s here: http://msdn.microsoft.com/en-us/library/aa561219.aspx
Did you get this to work ?
December 16, 2008 at 11:40 PM in reply to: Error : The message found multiple request response subscriptions. A message can only be routed to a single request response subscription #21407Hello sir…..
can you please tell me how i can retreive the message from WCF service…….i m trying to use the same steps whic i used to send the message to WCF service but here i m using WCF service as reciver but after deploy and importing binding info i m not getting any receive port and in orchestration binding not seen any receive service endpoint. Is i m following the right steps or is there any other way for it…..
please reply as soon as possible.
Girish
December 16, 2008 at 10:56 PM in reply to: Error with BizTalk Http Adapter and Custom Pipeline Component #21406Hummm… I really am sorry, but I’ve kind of run out of ideas. My only hint from here would be to start debugging the pipeline. Attach to BTSNTSvc.exe, breakepoints set in the Execute method of the component, run a message through the pipeline and see where it hits the fan. Besides that, I’m out of luck. Sorry.
//Niklas
December 16, 2008 at 5:30 PM in reply to: Error : The message found multiple request response subscriptions. A message can only be routed to a single request response subscription #21405hi…..i solved my WCF problem…….and find the exact steps for it……..yepeeeeeeeeeeeeee
You can run into a lot of issues when you re-version something. BizTalk uses a lot of hard references.
But for you specific problem, did you check to see if maybe it got deployed into another Application? Maybe the default Application?
Also, make sure if you have a Solution with many projects in it and you are deploying from Visual Studios that you do a full deployment of the whole solution and not just the Orchestrations. Or the will do just what you said and disappear.
December 16, 2008 at 2:53 PM in reply to: Error with BizTalk Http Adapter and Custom Pipeline Component #21403Hi Niklas
Thanks again for your reply. I tried implementing the method you suggested in the custom component but there was no change in the error message. It still appears to be missing some method in the component if the error message is accurate… ‘Reason: The method or operation is not implemented.‘
Any other thoughts would be appreciated.
Geordie
December 16, 2008 at 1:06 AM in reply to: Error : The message found multiple request response subscriptions. A message can only be routed to a single request response subscription #21401Thanks for reply sir…
actually my wcf service is not generating any proxcy file..i m not getting why? can you please send me the steps to follow for the same along with the configuration example..
Regards
Girish
Hi!
Connect a scripting-functoid between subRecord2 and the target-node where you need the count-value. Configure functoid script, select “Inline Xslt Call Template” and paste the following code:
<xsl:template name=”MyCountTemplate”>
<xsl:param name=”inRecord” />
<!– Below, the name of the target-node –>
<xsl:element name=”Field12″>
<xsl:value-of select=”count(./*)” />
</xsl:element>
</xsl:template>//Niklas – Connecta AB
December 15, 2008 at 8:09 PM in reply to: Error with BizTalk Http Adapter and Custom Pipeline Component #21399Thanks for the reply Niklas.
I’ll give it a go tomorrow and let you know how I get on.
Thanks,
Geordie
December 15, 2008 at 1:52 PM in reply to: Error with BizTalk Http Adapter and Custom Pipeline Component #21398Ok. I now recall having this issue in an earlier project. Use the stream.Can… -methods to see what you can do with it, if you cant do what you want, wrap it in another stream. This method we used to be able to read a an incomming stream from whatever (as far as we needed) it came.
/// <summary>
/// This method ensures that the stream is seekable so that it can be written to archive.
/// </summary>
/// <param name=”stream”>The stream to ensure is seekable.</param>
public static Stream EnsureSeekableStream(Stream stream)
{
if (!stream.CanSeek)
{
stream = new Microsoft.BizTalk.Streaming.ReadOnlySeekableStream(stream);
}
return stream;
}//Niklas
December 15, 2008 at 10:45 AM in reply to: Error with BizTalk Http Adapter and Custom Pipeline Component #21397Thanks for the response Niklas.
The only work done in the custom component is on the message stream. No other context properties are touched. The error also suggests that ‘The method or operation is not implemented‘. I am wondering if the Http adapter requires an additional method to be implemented in the custom component? It could also be access permissions but the modifications to the isolated host did not help.
Geordie
-
AuthorPosts