Forum Replies Created
-
AuthorPosts
-
Hi,
What do you mean by “empty adapter”? Is it that you can’t configure them? It seems like something went wrong in configuration of your BizTalk installation.
August 4, 2010 at 10:17 AM in reply to: Is it possible to choose the dimension of a target element by mapping? #25513Hi Wolfgang, thanks a lot.
But the Schemas are fix.
The question to ask is if there is a way to manipulate the iteration of a elemnt in destination.
For example:
We have: <Column1> <Row>HH</Row> <Row>FF</Row> <Row>GG</Row> </Column1>
<Row> has been repeated three times with different values (Row apreare only once in <Column1> with MinOccurs=0 and Max Occurs=unbounded in Schema A.xsd).
Now if I want to map <Row> (in A.xml) to <Row> (in B.xml) then the Iteration of <Row> in B.xml will be also setted to 3. In the next Step the values for this three elements (if nil, emty or something else) will specified.
My question is now, if I can prevent this method by mapping.
Hi Wolfgang,
If you do use message tracking, make sure that SQL Server agent is enabled so that the agent jobs that do periodic cleanup of MessageBox and Tracking databases are set up to run (so that those databases do not continuously grow and take up disk space).
As for your last question, I haven’t found much material on either Books Online or MSDN website explaining the different filter properties. so good luck with that.
Daniel.
August 4, 2010 at 8:50 AM in reply to: Is it possible to choose the dimension of a target element by mapping? #25511Hi Hiwa.
I don’t know I get you right and I don’t know what you will do after mapping.
But if you declare the <Row> as a Attribute of the Element <ColumnX> so you can fill it just if the source is filled otherwise it will not seen in the output xml file. But I’m not sure if this helps in your scenario. Also I’m not sure if it exist a property for your issue in the destination element.
Hope it helps or give some other ideas.
Wolfgang
Hello Daniel.
Yes, this helps a lot. I think for my scenario I can use message tracking for body. [;)]
Last question:
I was searching for a help site which explains all the filter proberties which are selectable – do you know one?
Thanks a lot for your help and tipps so far.
cheers
Wolfgang
I am using a Flat file disassembler (using a flat file schema) to receive an EDI file but I get the error “Unable to match the data in the input stream”. Other blogs suggest
1. Change encoding to UTF-8
2. Change parser optimization on the schema to Complexity
3. Change look ahead depth to 0
I tried all of these but I still get the error. Please help.
Hi Rafi,
I am not familiar with XMLA-type web services? Are they Java-based? In BizTalk 2009, you can use the WCF Adapter with WCF-BasicHttp binding to try to consume such a web service and see if it works.
Daniel.
Hi Wolfgang,
Here’s an MSDN article on Message Tracking in BizTalk:
http://msdn.microsoft.com/en-us/library/aa560149(BTS.70).aspx
I suppose you can run queries against the BizTalk MessageBox database or use a WMI script to fetch back messages, if that’s the scenario you are looking for…
Daniel.
yes my correlation is based on two value in the message : reference no + agency ID. Is this the cause of it?
August 4, 2010 at 3:04 AM in reply to: working with multiple incoming files at a single time` #25504Hi,
You must implement integration pattern called Convoy. It will aggregate all your messages to one, and then will send that message with all attached files.
Convoys/Aggregators are common for task you need to build, and there are different types of them: squential, time-out based, etc’
I think about something: is you get malformed message, maybe to make correlation based on more than one property? transport type + message type + something else?
August 4, 2010 at 1:49 AM in reply to: Filter for Different Messages comming to a single folder #25501Thanks Yonathan,
I was thinking of creating the property schema…. Thanks a lot for the suggestion. I will try now with this.
Rgards,
Hi Daniel.
Thanks for your information – I didn’t no (too much properties I can configure in BizTalk! ;))
Some more question – just to be sure. [:D]
There is no logging property I can activate for this Receive WCF SQL Adapter to see that this Adapter is running every five minutes (I have adjusted it)?
Or do I have to use the way you said … build another Send Adapter and set a filter for any messages coming form the Receive WCF SQL Adapter (when it is possible because it is a receive adapter)?
In case of use the tracking tab:
If I use the “Request message before port processing” property in the receive port, will this be a way to know each time the wcf sql adapter is running and if yes, how I hve to configure a new send adapter which is listening for this message?
Thanks a lot.
cheers
Wolfgang
Hi Yonathan,
thanks for your reply.
1. thanks and it quite similar to yours [:D]
2. yes, i created a correlation by using some filed in the incoming message but the problem i’m having is that when the received port received the message, the subscription(based on correlation) is gone but the message is having a value which not following the schema so we response back with the error. and now i want to enable back the subscription(receive port) so that the external system can sent the same request with the correct value in the message. right now when the system response back with the correct message, BizTalk will response with no subscriber error.
It works! Fantastic! Thanks a lot for you help. I wish I could find a good book on these advanced functoids.
Thanks again.
-
AuthorPosts