Hi there,
You can have one send shape at the end of the first orchestration that you should bind to a FILE adapter send port, and then configure the second receive location to look at the same folder.
you can do the same for the second orchestration.
HTH,
Mike
well, it depends on the integration pattern that you want to achieve,
for example, if you want to integrate with any MS access database no matter what design/tables it holds, you might end up writting your own WCF LOB adapter (which is not that difficult)
but if you want to integrate with a certain database, you can write ur own wrapper (Class library, Web Service, Or WCF service) using office APIs
Hello Mr. Kumashi,
it’s possible to use the SQL adapter to poll a table for changes using a preset query, check this link for reference.
HTH,
Mike
Hi All,
is it possible to continously poll a table / view for changes . The View is non updateable in nature.
Any suggestions will be regarded
Thanks
Vinayak Kumashi
HI Sangeeta,
I am using BizTalk 2009 and have to use RFID Adapter, is you have any contains for the same which will help in implementation of RFID Adapter.
Regards
Girish Fuluskar
Thank you for your reply Daniel.
I have tried that, it didn’t work.
Hi,
Generate an instance of the web request message, and assign that XML string as the parameter to the LoadXml method of your variable of type XmlDocument, that will initialize your message part.
Daniel.
Hi Daniel.
Thanks a lot … yes, I will give it a try! [;)]
Wolfgang
Hi Wolfgang,
If your message contains bad or unexpected data that would trip up your orchestration, then you would implement exception handling in your orchestration to allow it to terminate nicely (and not be suspended) so that your message queue does not get backed up…
Daniel.
Hi,
I’m looking at the error message you pasted in your original post, and these two lines caught my eye:
The type must derive from System.Web.Services.Protocols.SoapHttpClientProtocol.
The type must have the attribute System.Web.Services.WebServiceBindingAttribute.I wonder if you tried adding the Microsoft assembly System.Web.Services to your References folder in the project where you are adding the web reference and see if that resolves the web service invocation warning issue.
Cheers,
Daniel.
Hi.
Thanks for your helps and tips. Nice to know there are some more ways to go! 😉
First I tried the way with the “globalVariable” – but I didn’t get the value of the variable to another page. I did it like greg wrote and used it in another scripting functoid on page 2. The compiler didn’t brought an error because of the “new” variable in the code, so I know the variable was recognized in the code. I will do some further checks, why the variable will loose the value if I use it an page 2…
But thanks again for your help so far.
Wolfgang
Hi Daniel.
Thanks for the tip and information. I did some searching on that and now I know what are correlations are for! 😉
But what will be, if a message goes wrong and the orchestration can’t finished (could that be), in this case all messages behind can’t go further till this message will be terminated, is that right?
Thank you very much.
Wolfgang
Thanks Daniel for your suggestion.. But the problem is I have different Orchestrations. and all those incomming msgs are of different schema types.
In my case my 1st Orc is doing a database insert and on basis of that the other orchestrations are performing their tasks. So in anyway i need to use the 1 receive location first ten the others.
Regards,
Ram
1º Yes, I did that, although IIS log does not show any access attempt when I try to call a webservice;
2º Yes, it works from a console application using a regular web reference;
3º Yes, it didn’t work;
4º Yes, I always give different names.
One thing I find odd is when I add the webreference, the Reference.odx.cs file is generated but comes empty.. Couldn’t find why yet.
Hi Ram,
There’s no out-of-the-box functionality in BizTalk to handle your scenario. You could have an orchestration (associated with your Receive Location 1) pick up the messages, then wait 10 seconds (in a Delay shape) before calling a C# helper class that runs a WMI script which will enable your 2nd Receive Location, and so on. That can be a work around solution.
Daniel.
-