Forum Replies Created
-
AuthorPosts
-
Hi,
First of all, I suggest that you make sure that you correctly configure your SAP web service, following the guidelines stated in this link:
http://www.riyaz.net/sap/xipi-a-guide-to-using-sap-xi-soap-adapter/113/
If you still have an issue trying to consume this SAP service in your BizTalk orchestration, the next step that I recommend is that you try the solution proposed in the following blog and see if that resolves your issue:
http://seroter.wordpress.com/2007/04/02/consuming-web-services-in-biztalk-without-web-reference/
Let me know how you make out on this one.
Good luck.
Continuing with the same topic … Now I get the following error:
source: XLANG/s
xlang/s engine event log entry: Uncaught exception (see the 'inner exception' below) has suspended an instance of service 'MYORCHESTRATION'.
The service instance will remain suspended until administratively resumed or terminated.
If resumed the instance will continue from its last persisted state and may re-throw the same unexpected exception.
InstanceId: 2ab8af38-1b36-4a41-b066-27ec8686e7e2
Shape name:
ShapeId:
Exception thrown from: segment -1, progress -1
Inner exception: Server Error
Message ID: {182611EC-711D-43B1-A3D7-5D07E41D5805}
Instance ID: {32297CC3-B3E0-4934-8C15-EC95CC2AB990}
Error Description: Server Error
Exception type: XlangSoapException
Source: Microsoft.XLANGs.BizTalk.Engine
Target Site: Void VerifyTransport(Microsoft.XLANGs.Core.Envelope, Int32, Microsoft.XLANGs.Core.Context)
The following is a stack trace that identifies the location where the exception occured
at Microsoft.BizTalk.XLANGs.BTXEngine.BTXPortBase.VerifyTransport(Envelope env, Int32 operationId, Context ctx)
at Microsoft.XLANGs.Core.Subscription.Receive(Segment s, Context ctx, Envelope& env, Boolean topOnly)
at Microsoft.XLANGs.Core.PortBase.GetMessageId(Subscription subscription, Segment currentSegment, Context cxt, Envelope& env, CachedObject location)
at MYORCHESTRATION.segment1(StopConditions stopOn)
at Microsoft.XLANGs.Core.SegmentScheduler.RunASegment(Segment s, StopConditions stopCond, Exception& exp)
and the next error:
A message sent to adapter "SOAP" on send port "PORTNAME" with URI "MYWEBSERVICE" The system cannot find the path specified.The system cannot find the file specified.The system cannot find the file specified.The system cannot find the file specified.The system cannot find the file specified.The system cannot find the file specified" is suspended.
Error details: Server Error
MessageId: {182611EC-711D-43B1-A3D7-5D07E41D5805}
InstanceID: {32297CC3-B3E0-4934-8C15-EC95CC2AB990}
ERROR: Server Error???????????????????
You might have too, even Attunity, the company that wrote the Microsoft connector to Teradata for SSIS msdn.microsoft.com/…/ee692365%28v=sql.100%29 hasn't got a BizTalk adapter listed. http://www.attunity.com/…/36326.aspx
Hi anonymous,
I came across this webpage on the Teradata’s website for downloads, regarding an installation package for Teradata Tools and Utilities, which includes Shared ICU library for TeraData and TeraData GSS (mentioned in one of the posts on this thread). You will have to create an account in order to do the download of the package.
Hope this helps.
One question – how do you connect to Teradata from BizTalk? Do you use any adapter? or custom adaper?
We need to connect to Teradata and would like to know how to do that
August 27, 2012 at 11:19 PM in reply to: Copy outbound properties to inbound message from same send port #25854Hi,
Assuming that you exposed your orchestration as a WCF service, configure the send port of that orchestration (the one that sends the response back after you send the request to the service) as a direct bound port, so that it publishes the message directly to the MessageBox, and thus triggers subscriptions from any other matching send ports (when you configure the filters for those).
Hope this helps.
Hello,
Thanks for the reply . I have to use typed polling as the i need the schema for mapping.
The View i am polling is non updateable , meaning as soon as i read records , i have to set a flag , indicating the record is read, but the view does not permit me to do so , as it is read only.
Mean While , can the polling behavior be achieved on non – updateable views ? Be it using any polling mechanism?
thanks
Vinayak kumashi
Sorry – for the last post – I didn’t read it carefully.
When you define Send Port – (if I get it right you get request – send to WS – get response – return the response to user – right?)
So, if you do use WebPort types – after you deploy the project – and when you define send port with SOAP protocol, did you define your BizTalk assembly in “WebService” tab?
http://i080.radikal.ru/1009/0c/cba0017aead4.jpg
Not SALE files – (if you have any) – what do you intend to do with them?
I would wright a windows service, which would check your directory and look for SALE prefix files. after find one – move that file to another folder/SQL table as blob. After you get some files (let’s say 5) – you collect them and send as non XMLbut – in what way? binary? blob? CDATA? who/what expects to receive those files?
Say, after defining messafes according to your generated schemas – do you use WebPort type? (right click on port surface area – new port port name – port type – use existing port types – select from “WebPort Types” – your port)?
According to this error/post http://www.eggheadcafe.com/software/aspnet/30267049/setting-webservice-destination-programmatically-at-runtime—.aspx
Hi Wolfgang,
Have you looked at the Context Accessor Functoid from CodePlex website?
http://contextaccessor.codeplex.com/
Daniel.
September 1, 2010 at 9:58 AM in reply to: Biztalk 2009/2010 – Converting flat file to X12 file #25845Batching is handled by parties in BizTalk. Have you created at least one party for a trading partner?
Hi.
Yes, a good idea. I will have a look at it.
Thanks a lot.
Wolfgang
Please correct me if I’m wrong, but as I understand it BizTalk maps execute by building the destination from the top down. I would suggest linking the script functoid that sets the global variable on page 1 to the root node of the destination schema to ensure that it executes prior to any other node.
September 1, 2010 at 8:57 AM in reply to: No Disassemble stage components can recognize the data #25841Try using a flat file disassembler component instead of the XML disassembler component in your custom pipeline.
-
AuthorPosts