Forum Replies Created
-
AuthorPosts
-
May 1, 2008 at 10:33 PM in reply to: HL7 Accelerator 2.0 for BizTalk 2006 R2: Installation issue #19531
Yes I’d. This problem occurs only on Developer Edition, since HL7 Accelerator’s setup checks for Installed BizTalk versions to be Standard or Enterprise edition when you press that damn Next button
May 1, 2008 at 3:15 PM in reply to: HL7 Accelerator 2.0 for BizTalk 2006 R2: Installation issue #19530I am having the same issue with the HL7 accelerator and was wondering if you had fixed this problem?
Thank you Nick.
It works fine when I use custom EDI receive and EDI send pipes. I am not sure how come it could not work with default EDI receive and EDI send pipes.
I have another issue now:
I have an issue in receving EDI file. When EDI message have “%u00e5” or similer to these
characters EDI message is susspend by receive pipe line. How can i allow all
characters?
I tried the following set up.
EDI receive pipe line’s Character set : UTF8, no luck
character set: Extended, still no luck.
I tried with and without EDI TYPE – Extended Validation in party properties. still no luck.Thank you in adavance,
SivaMay 1, 2008 at 12:48 PM in reply to: How to return xml message as a string from an orchestration published as web service? #19527Hi Sidhu,
What did you to get it working. Let others know it may help someone in future.Thanks,
GrdCan you advise how you are trying to undeploy – is this through the BizTalk Administration Console or in Visual Studio.
Also, can you advise on your infrastructure: is both BizTalk and SQL Server installed on the same box or separate boxes?
Regards, Nick.
Siva,
Although I normally do traditional EDIFACT, having a look at your error message seems to suggest that the Transaction Set Identifier is missing. Furthermore, the erorr message The X12 transaction set with id ” contained in functional group seems to suggest that the Transaction Set Identifier is in fact missing.
I’m presuming that a Transaction Set Identifier is similar to an EDI Interchange identifier – is it possible to supply this value and re-run the message?
Regards, Nick.
Anon,
Thanks for the comment re. the double-slash. I’ve never used inline-xslt in anger before, I’ve always gone to straight custom XSLT files where I can do (for example):
/ns0:Root/ns0:child/ns0:value
However, when I put together a test project for this post, I discovered that that wasn’t accepted. A blog post I found suggested that the double slashes was the answer. I’ll bear the performance issue in mind in the future.
Cheers, Nick.
Thank you!
May 1, 2008 at 8:34 AM in reply to: How to return xml message as a string from an orchestration published as web service? #19522Thanks all,
It’s working.
Tejas,
Using the %datetime% macro in the FILE adapter should work without issue, however there is no need to wrap it in angled brackets (i.e []). You enter the macro in the File name text box when configuring the FILE adapter.
However, you mention the file connector and not the adapter – are you sure you’re using the file adapter?
Nick.
Thanks Mate!
My NZ English isn’t very qood. I will try it….
Mike
Thanks for the help! That is what I suspected.
Mike
AK,
I would recommend exposing your MSG1 schema as a web-service (see http://iaimtomisbehave.org/2007/12/12/how-to-expose-your-schemas-as-web-services-in-biztalk/) and on the receive port of that web-service use an inbound map to transform MSG1 to MSG2 which is then subscribed to by your orchestration. The response message would need to be transformed back to the MSG1 response message on an outbound map in the receive port (don’t forget your receive port will be solicit-response, not one-way).
So, you’re not exposing the orchestration as a web-service but the schema that represents MSG1.
Hope this helps, Nick.
May 1, 2008 at 5:23 AM in reply to: Can you publishing an orchestration as a WCF service and move the service to a different server? #19516You can only host WCF receive locations on the Biztalk server.
Check the .svc file, it references the following class:
Microsoft.BizTalk.Adapter.Wcf.Runtime.CustomWebServiceHostFactory, Microsoft.BizTalk.Adapter.Wcf.Runtime, Version=3.0.1.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35
This is part of the Biztalk install and will only be present on a Biztalk server.
Isolated adapters handle the message in a non Biztalk host process, in this case IIS. The entire message receipt, pipeline processing and publishing to the message box is all done on in the IIS process.
Just a small comment on that –
If you can, you should avoid using ‘//’ in xpaths anywhere.
In many cases this is just laziness which results in a significant performance hit.
when you use ‘//’ the xsl engine has to scan the entire document to find ‘Page’ elmenets; if you know where they exist in the document you should specify that explicitly.
-
AuthorPosts