Forum Replies Created
-
AuthorPosts
-
January 30, 2009 at 3:51 PM in reply to: How to Debug a Custom C# Component Called by BizTalk #21612
Hi Everyone,
After abandoning this issue for almost a year, I finally resolved this issue, and thought I’d share the solution for anyone else who has this problem in the future.
The short answer is that I didn’t go far enough. After I built the component in debug mode, I correctly GAC’ed the DLL and updated the reference for the calling project to point to the Debug version and updated the Admin Console Reference to the Debug version, then restarted the Host Instance.
At this point, when I did “Attach to Process” within the custom component, the breakpoints were still appearing with the same message as before: “The Breakpoint will not currently be hit. No Symbols have been loaded for this document.”
However, when I “ignored” this error and proceeded with submitting a message through BizTalk, the custom component “woke up” and realized that it was going to be called. The breakpoint errors went away, and debugging worked exactly as it was supposed to!
YAY!
Thanks to those of you who pointed me in the right direction.
Thank you all for your quick replies . Like i said a few posts above i already found out how to use the webservices.
I only have one Problem left ,my webservice is just a stub. It wants a CustumerID as a parameter and returns a string .The Problem is that the expected CustomerID is an System.Data.SQLtypes.sqlint32 Datatype, Now if i want to assign the node to the to the WS.reqeust message it gives me an error that BT can’t convert System.Data.SQLtypes.sqlint32 to INT.Does anybody have a clue?
Thanks Amar
Add the FILE.CopyMode property to your message with a value of 2.
If I remember correctly, the reason for this might be that ExplorerOM depends on some of the ENTSSO assemblies, some of which are unmanaged code (and possibly only available in x86… or the ExplorerOM code simply was not written to automatically use the right platform-specific version, which can be tough).
Can you post an example of the input document?
January 30, 2009 at 6:50 AM in reply to: Custom Pipeline Component Adding Rootnode and NameSpace #21607I think your idea of using an Xml.XmlDocument as the receive type would most likely provide the most flexibility. Then on the response you could see what the root node is and handle it appropriately.
Here you go!
Hi,
You can retrive the node values in two ways..
1)using property schema
2)using Xpath Query in Expression Editor
once u added the Webservice reference it will give u two messages-Request and Response….so send Request through by configuring Send Port and Get Response using Receive Shape…
Thanks
Sri
I have faced this issue too.
When we compile with Platform:x86 switch then the application runs on 32 bit host instance not the 64 bit host. Then we can not get the advantage of 64 bit.
Only option that I found to use the below . Hope this will help you
// Query for the BizTalk Receive Location.
private const string queryCom= “SELECT * FROM MSBTS_ReceiveLocation”;string receiveLocationName = string.Empty;
//Create the WMI search object.
ManagementObjectSearcher Searcher = new ManagementObjectSearcher();// create the scope node so we can set the WMI root node correctly.
ManagementScope scope = new ManagementScope(“root\\MicrosoftBizTalkServer”);
Searcher.Scope = scope;// Build a Query to enumerate the MSBTS_ReceiveLocation instances if an argument
// is supplied use it to select only the matching URL.
SelectQuery selectQuery = new SelectQuery();query.QueryString = queryCom;
// Set the query for the searcher.
Searcher.Query = selectQuery;// Execute the query and determine if any results were obtained.
ManagementObjectCollection queryCol = Searcher.Get();//Get the Recive Location Name from InboundTransportURL property
foreach (ManagementBaseObject envVar in queryCol)
{
PropertyDataCollection envVarProperties = envVar.Properties;
foreach (PropertyData envVarProperty in envVarProperties)
{
if ((envVarProperty.Name.Equals(“InboundTransportURL”)) &&
(inboundAddress.Equals(envVarProperty.Value)))
{
//Set the reciveLocationName from the InboundTransportURL property
receiveLocationName = envVar[“Name”].ToString();
break;
}
}
}Regards,
Nandika
I myself managed to fix this problem..Please ignore
before call webservice use MessageAssignment ( to set the value means to say the web service need some parameter set the parameter value with you XSD element value ) the call the webservice …if you add the reference of webservice to your biztalk application it will automatically create the PortType use that port type it will be SOAP type and direction will be Send and Received
if you need help let me know i will write the each steps
regards
Akash KB ([email protected])
Hi,
U can unconfig the Biztalk Server Configuration and configure with remote server name…be sure all the configuration setting showing green …be sure the all the server come under SSO.
Akash KB ([email protected])
HI
Thanks. biztalk requires sql server alwys ? Can we have some application where we don’t use sql server with biztalk?
I tried as you said. it is is saying can not connect to server. Now i will look at why sql sserver is not getting connected.
thanks for pointing me to my error.
will come back aftre I connect to sql server
You need to connect to your group. Right click on BT Server 2006 Administration & select Connect exsiting group. Then give your SQL server name & BT mgt db name
Hi there, there are few scripts to be run on both the BizTalk and SQL Server, but you should have followed the log shipping instructions before moving the databases. Please review this page:
-
AuthorPosts