Forum Replies Created
-
AuthorPosts
-
solved by removing it and adding it in
http send port property : content type
Thanks for replying,
I have the same issue if i remove it ???
Hi Sangeetha,
This issue appears to be related to a known Microsoft issue in which a service may not start before a defined timeout. The issue is more likely to occur if your computer is heavily loaded, or if the installation is within a VMware image, resulting in generally slower performance.
SOLUTION:
Increase the timeout value for service startup process to give it more time to load when the computer (or VMware image) starts. To do so, use the following procedure.1. Click Start, click Run, type regedit, and then click OK.
2. Locate and then click the following registry subkey:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
3. Right-click Control, point to New, and then click DWORD Value.
4. In the New Value #1 box, type ServicesPipeTimeout, and then press ENTER.
5. Right-click ServicesPipeTimeout, and then click Modify.
6. Click Decimal, type the number of milliseconds that you want to wait until the service times out, and then click OK. Typically, a data value of 35,000 is sufficient to keep the service from timing out. However, you can reduce or increase this value according to your specific startup requirements. For example, to wait 60 seconds before the service times out, type 60000.
7. Quit Registry Editor, and then restart the computer.
See complete details on the Microsoft issue at the following knowledge base article:
http://support.microsoft.com/?kbid=884495See additional details for events 7000 and 7011 on Windows 2003 at the following knowledge base article:
http://support.microsoft.com/kb/922918/en-usAll The Best,
Pavan.
Hi,
I found this useful article describing how to set up a clustered Enterprise Single Sign-On service (to configure BizTalk Server on multiple NLB nodes):
http://geekswithblogs.net/mhamilton/archive/2005/05/01/38783.aspx
I hope this will help you troubleshoot and resolve your issue.
Daniel.
I have a web cast that describes how to connecto to SAP using the BizTalk Adapter Pack 2.0 adapter. You can find the webcast here:
http://www.cloudcasts.net/ViewWebcast.aspx?webcastid=2521554266599869567
I have run into some similar situations with other adapters such as POP3, FTP and SAP(dot net connector version) since they are not supported in a 64 bit host instance. I have not noticed any negative effects of running Receive or Send operations in a 32 bit host instance and running orchestrations in a 64 bit host instance.
In terms of 64 bit performance here are a few advantages: “…faster messaging/orchestration processing or the larger addressable virtual memory of 64-bit mode for large BizTalk message mapping or other memory intensive operations.” from http://social.msdn.microsoft.com/Forums/en-US/biztalkgeneral/thread/fe3c54df-548f-4279-b01b-816e5c2e52c3
You may want to consider modifying your host instances to have a delayed start. Check this link for more details.
1) Yes, they should be the same
2) Any pipeline component used in the disassemble stage needs to have this interface implemented. It looks for that interface.
3) I have never used these tools to debug a pipeline, but some friends of mine swear by them: http://msdn.microsoft.com/en-us/library/aa547988(BTS.10).aspx
Hi,
You might want to check out the following articles to see if there is something you missed when installing/configuring BizTalk in your NLB environment:
http://msdn.microsoft.com/en-us/library/ee251708(BTS.10).aspx
Good luck,
Daniel.
Hi,
This could be a networking issue in your clustered environment. Check out the following MS KB article:
http://support.microsoft.com/kb/323431/en-us
Good luck,
Daniel.
micbox,
I’m not too sure, however given that you can see the C# that is created from an orchestration when it is compiled…
You could try both in the same orchestration, compile it and look at the C# to determine whether one ‘looks’ more efficient than the other. I would imagine that the decide shape will be compiled into an if…then statement.
One further point to consider is whether you will actually see any real performance benefit of doing the branch as if statements or decide shapes. I would suggest that in this case readability is more important than any performance gain you are likely to achieve. I always adopt a decide shape over if…then in an Expression Shape as the latter hides the meaning of the code, especially when you are looking at the orchestration in the debugger.
Hope this helps, Nick.
Nick.
Hi Sangeetha,
I usual get this error when I attempt to restart a BizTalk Host Instance from the services window, but the Host Instance normally comes up Ok when I try and do a ‘Start’ (after this failure).
Can you try and Start the service and see whether your application is working as expected?
Nick.
Thanks, you’re a genius…AssemblyInfo.cs worked for me.
Seems to be if you’ve converted your code from a previous version (in my case BizTalk 2004).
Thanks.
Simon.
Thanks for your response.
MSDTC is configured on this machine exactly with the same way. Any other possible reason that could be causing this issue?
Thanks!
-
AuthorPosts