Forum Replies Created
-
AuthorPosts
-
Yonathan,
Thank you very much for your reply.
[quote user="Zx7R"]
2. GO to your construct shape, type xDoc.LoadXml(“<Root><YourInstance here><></Root>”); – BTW, you must put the text between ” ” signs and not ‘ ‘ <<< see the difference?
[/quote]
I typed xDoc.LoadXml(“……”); in the expression of Message Assignment shape within the construct shape. Is it correct?
[quote user="Zx7R"]
3. After that, you choose your message, which is of type of request schema and do like thie:
[/quote]
Is it the message in the Messages folder on Orchestration view?
[quote user="7x7R"]
msgRequestToSQL = xDoc;
msgRequestToSQL(*) = msgYourSomeMessage(*);
[/quote]
where can I add those lines?
I appreciate your help.
Lynn
It is now supported in BizTalk 2010. Only took a little while [:)]
1) I need to name of each attachment.
2) I have used
msgEmailOut = varXmessage[n];
MsgPart=varXmessage[n];
msgEmailOut(FILE.ReceivedFileName) = MsgPart.Name;
n = n + 1;
3) when i send 2 pdf files – a) Test1.pdf
b) Test2.pdfI have 3 files frop at my location
a) Test1.pdf
b) %SourceFileName%
c) {D0899C9C-F115-44EB-98E8-072CFAD9B0A0}and when i debug – I do’t see and MsgPart.Name
Hi, please clearly exaplain the loop i am new for the Biztalk. how you solved.
where exactly create the SAP-Out variable etc.? if possible pls send souce code to me
Hi,
Not Message_1 (you defined not a variable but a message), but this steps:
1. Go to Orchestration view window, there you can see a folder called variables. Right click, new variable, give it name lets’ say xDoc – choose type XmlDocument.
2. GO to your construct shape, type xDoc.LoadXml(“<Root><YourInstance here><></Root>”); – BTW, you must put the text between ” ” signs and not ‘ ‘ <<< see the difference?
3. After that, you choose your message, which is of type of request schema and do like thie:
msgRequestToSQL = xDoc;
msgRequestToSQL(*) = msgYourSomeMessage(*);
And send as request this msgRequestToSQL message.
Here is very helpful tutorial
MSMQT is not the same as MSMQ. To set MSMQ properties like that you need to add a reference to the Microsoft.BizTalk.Adapter.MSMQ.MsmqAdapterProperties.dll assembly. This can be found in the biztalk install directory.
June 25, 2010 at 11:47 AM in reply to: BizTalk Server 2006 SOAP-adapter problem with proxy server #25060Is your Web service – asmx or WCF? Did you try to increase size of maximum lenght of data?
Also set timeout to bigger value (on IIS if your service resides there)
June 25, 2010 at 11:43 AM in reply to: Enterprise SSO Configuration Failure during BizTalk 2009 configuration – Message: "(0x80070002) The system cannot find the file specified." #25059Did you try to remove installation and reinstall?
Exept being a local admin – you must give permissions on SQL server for SSO admin (thew user account under which this service runs).
But it seems that reinstall can help.
June 25, 2010 at 8:58 AM in reply to: Enterprise SSO Configuration Failure during BizTalk 2009 configuration – Message: "(0x80070002) The system cannot find the file specified." #25058No solution found.
I decided to develop on my machine and deploy in another one where I have already installed successfully BizTalk Server 2009.
I’m sorry!
June 25, 2010 at 5:51 AM in reply to: Enterprise SSO Configuration Failure during BizTalk 2009 configuration – Message: "(0x80070002) The system cannot find the file specified." #25057I’ve got the same error, you ever found the problem for this?
Hi VK,
Have you looked at the following MSDN article?
http://msdn.microsoft.com/en-us/library/aa561963.aspx
Daniel.
I solved this by letting the admin of the webserver add:
Content-Type: text/xml; charset=utf-8
to the http header of the webservice. So apparently Biztalk can’t properly recognize an http response as utf-8 when the http header doesn’t contain the charset.
Any ideas on how to do this if you don’t have access to the webservers http responses?
Regards,
Bart
Thanks Greg for your help, my current static schema looks like below
Header
@ID 0-8
Data
@A 8-17
@B 17-26
@C 26-40
-> Now Issue is this that in this Data segment we will need to add more attributes by passage of time with variable lengths, so we need some generic thing here that pipeline could resolve this in xml no matters if at one time i send 3 attributes under this Data segment or 5 in second time…….,
So, if generic flat file schema could be used here for problem like above, can you explain how we will use that?
Thanks again…
u have to use WSS adapter where need to do the setting of teamlink url / user name / password..
The Flat File Disassembler only works from a static schema definition.
Depending on what is changing in the flat file and how it is changing you may be able to use optional records and fields in your schema to cope with the change.
Or you may like to use a generic flat file schema and use a component in the pipeline to call an Xslt from a file to create the output message you need.
Or you could write your own custom disassembler that works from a config file.Can you give us an example of what is likely to change in this file?
-
AuthorPosts