  • in reply to: How do I update a BizTalk from VisualStudio 2005 #22461

    When you rebuild and deploy a Biztalk project you must restart the host instances that this application uses.
    For in-process hosts instances (as in your case), use the Biztalk Admin Console, Biztalk Group,Platform Settings, Host Instances.

    The host instance is a running service that loads the BizTalk assemblies, if you redeploy an assembly the host instance will continue to use the original assembly until restarted.

    in reply to: MessageId #22457

    When I try to match the filename (created using the default %MessageID% macro) of the message that was sent with the message(BTS.MessageID) they are not the same. Am I doing anything wrong?

    Note: In my orchestration I create the message, send the message, and then I check Message(BTS.MessageID)

    Also checkout the CRM4 adapter installation guide

    Steps to deploy CRM4 Adapter
    —————————–

    STEPS 1 & 2 to be completed on BIZTALK Application SERVER

    1. Install CRM3 Adapter
    2. Download hot fix for CRM4 Adapter and install it (Can be installed only where CRM3 adapter is already installed).

    STEP 3 to be completed on CRM APPLICATION SERVER

    3. Now to deploy CRM4 adapter do the following (VERY IMPORTANT FOLLOW THE STEPS ACCURATELY).

        I. Create a folder called ‘xsd’ in the ‘SDK’ folder under ‘CRMWeb’ sub folder under CRM Server installation root directory i.e “Drive\Program files\Microsoft Dynamics CRM Server\CRMWeb\sdk”.
            For Example “C:\Program files\Microsoft Dynamics CRM Server\CRMWeb\sdk”

        II. Copy “entity.aspx(3KB)” from the STEP 1 i.e “DRIVE\Program files\BizTalkAdapter\KB946649” to the above xsd (create in step 3 of I) folder
       

    Adapter is developed for CRM 3.0 but with minor tweaks can be used with CRM4 so, it doesnot support Organisation in the URL so u should use

    http://<CRM server>/msCRMServices/2006/

    in the CRM adapter URL

     

    in reply to: Promoting Schema element error #22451

    When you are specifying Distinguished Fields you are unable to modify the name.
    You can use promoted properties instead.
    1. Create a property schema and define a property called SourceID
    2. In the schema promote the property and specify your property schema and link the <source-id> node to the SourceID property
    3. Assign a value:   QofDATFile(MyProperties.SourceID) == “ABC”

    Alternatively you can follow Guo Ming Li’s suggestion of using the xpath function

    in reply to: Promoting Schema element error #22450

    You could use the built-in xpath function to set the value of any element. You could find more information here:  http://msdn2.microsoft.com/en-us/library/aa561906.aspx 

    If your goal is only to move a file from one location to another, you can setup a FILE send port with filter to subscribe any message/file that’s coming from a specific send port, location that meets certain criterias.

    Otherwise, you could write all your code in a helper .net class and call your function to write move the file to the new location. Hope this helps.

    Hello!

    So if I just want to have a map to the output xml file I assume that I can chose  
    the receive port or the send port. It seems to me that it doesn’t matter.

     

    //Tony

    There are three standard ways you can use a map in Biztalk.

    1. Use a transform shape in an orchestration.
    2. Add the map to the Receive Port
    3. Add the map to the Send port

    An orchestration is probably not suitable for your messaging only solution.
    You can use the Biztalk Admin Console to specify a map on the ReceivePort

    This depends on how you define your flat file schema.

    If your structure  contains a root element with an unbounded record element the you will get one output file.
    If your strusture on defines a single record element then the flat file diassembler will debatch the incoming flat file into multiple messages. 

    Thanks very much very good explained!

    I understand all of it but I just wonder if this will create one xml file with all the detail records from the csv flat file or
    if it will create one single xml file for each detail record in the csv flat file.

    I want to have one xml file with all the detail record from the csv flat file within

    //Tony

    Thanks very much very good explained!

    I understand all of it but I just wonder if this will create one xml file with all the detail records from the csv flat file or
    if it will create one single xml file for each detail record in the csv flat file.

    I want to have one xml file with all the detail record from the csv flat file within

    //Tony

     

    You need to parse the flat file into an Xml message. This is done by the Flat File Disassembler (FFDASM), a standard pipeline component.

    1. In your Biztalk project, add a receive pipeline.
    2. From the tool box, drag the FFDASM into the Disassemble stage of your pipeline.
    3. Select the FFDASM component in the pipeline, and in the properties window set the Document property to your flat file schema that your have created.
    4. Build and deploy your assembly.
    5. In your receive location, set the receive pipeline to the custom pipeline you have just created.
    6. Restart the host instance

    in reply to: Schema property promotion and envelop schema #22439

    The problem is not in your schemas, but in some odd behaviour in the XmlDisassembler. This could be worth a bug report.

    When you promote the RegWaitID value as both a promoted property and distinguished field in a single message both are promoted into the message context.
    However, if your message is part of a debatched interchange only the distinguished field is put in the message context.

    If you remove the distinguished field and only use the property promotion, then the property is promoted.

    in reply to: Calling a stored procedure in an orchestration #22438

    Error #1: use of unconstructed message

    This indicates you are using a message that has not been constructed. This is usually cause by one of the followigs:

    1. message is not constructed before it’s used, i.e. not constructed inisde a “Construct Message” shape, or it’s not constructed inside a construct statement. You can use one of the methods described here: http://blogs.objectsharp.com/cs/blogs/matt/archive/2004/11/09/1009.aspx
    2. “an activatable receive must be the first executable statement in a service”: the first shape has to be a receive shape with “Activation” property equal to true if the orchestration is to be started by an arrival of a certain message