Forum Replies Created
-
AuthorPosts
-
Thank you. It worked.
My biztalk solution could be 2006 or 2009.
Unfortunately BT (orchestration engine in particular) does not give us absolute control over this process. This can not be done programmatically, it’s under contol of orchestration engine. You can configure certain aspects in Biztalk’s configuration file (defalut config file doesn’t even list these values but it uses default values) but this is probably not what you’d ultimately want. For example, [by default], an orchestration will wait for 1800 sec at receive location before dehydrating. For send ports it may keep history of how long it used to wait and based on that value dehydrate.
Hi,
It seems to me that both your orchestrations’ maps share the same HL7 schema. Customize the HL7 schemas so that their namespaces are different, re-link them to your maps, and re-deploy your orchestrations. I hope that’s what’s causing your problem.
Daniel.
Hi Sangeetha,
Try this connection string:
Provider=SQLNCLI;Server=CC-DT-IT-01;Database=EDICrossReference;Trusted_Connection=yes;
Daniel.
I think someone else is trying to do what you are doing. Try this link, it only uses the SOAP adapter
Hi Siva,
See the discussion on this other BizTalkGurus thread: http://www.biztalkgurus.com/forums/t/10739.aspx
In BizTalk 2006, outside of an orchestration, it looks like you will have to use the Wcf-BasicHttp adapter in your Send port to get to the SOAP Header, not the regular SOAP adapter.
Best,
Daniel.
Thank you Daniel,
I checked the link. It gave me some tips to work on this. However It haven’t explain how can i build SOAP-Header. It is just talking about SOAP-Body only.
Thank you Brunchey,
I cannot use the WCF. I will check these links.
Hi Siva,
Check out the following article that shows how to consume a web service in a messaging-only scenario in BizTalk 2006:
Hope this helps,
Daniel.
Thanks on this answer,
Acctually I already found the solution for this problem.
I did that with Logical String functionid.
Regards,
Check your event log properties. If it’s full, change your settings or clear the log.
I think you are going to have to either make use of some complex mapping, using lots of functoids, or make use of a scripting functoid to achieve this.
Assumming all the ExtraHeaderNotes elements are present even when empty, you should be able to make use of some logical String funtoids to check the value of each element and then use the output from these, in conjunction with a few Equals functoids, some AND functoids and some Value Mapping functoids to control which of the values gets mapped.
e.g.
If (ExtraHeaderNotes1 is string) and (ExtraheaderNotes2 is not string) and (ExtraheaderNotes3 is not string) map ExtraHeaderNotes1
If (ExtraHeaderNotes2 is string) and (ExtraheaderNotes3 is not string) map ExtraHeaderNotes2
If (ExtraheaderNotes3 is string) map ExtraheaderNotes3
Not that easy to explain in text but I hope you get the idea!
We have now carried out extensive tests using this scenario, and can report that we did see gains in performance, although not huge ones.
In our scenario, the server was often maxing out the single CPU it had, under peak load this resulted in time outs on the front end that was calling our BizTalk web services.
With the second processor addeed the BizTalk host processes defaulted to running on processor 0.
Under average load we saw that CPU 0, running the BizTalk host, was still busy but didn’t max out. Under peak load CPU 0 continued to max out but we did not see the timeout issues we were getting previsouly. In the peak scenario the second CPU was running at about 50%.
This suggests that if you have a very busy BizTalk 2004 standard server you may see benefits from a second CPU.
-