Forum Replies Created
-
AuthorPosts
-
Not always, but it is recognisable pattern, see: http://en.wikipedia.org/wiki/Byte_order_mark
You need to read the first few bytes of the stream to determine if there is a BOM and then you can ascertain the encoding used. No BOM usually indicates an ANSI encoding.Hi,
See the following MSDN forum thread for more information on how to do that:
Daniel.
Thank you Greg,
Does it always be at the front of xml?
This is probably the BOM, byte-order mark used to define the encoding being used. You need to remove this before adding your “xmldata=” string.
It looks like map is the reason for the “?”. If i don’t use the map then “?” does not added with “xmldata”.
Still I haven’t fix the issue.
Thank you for your quick reply Daniel.
Our customer wants “xmldata=” at front of the xml that we send over HTTP. Cusotmer PO request xml is something like <PORequest><POHead>……..
I need to send something like xmldata= <PORequest><POHead>……..
So I created custom com to add “xmldata=” in send pipeline Encode section.
Hi Siva,
Are you trying to add an attribute to the document declaration type for your XML data (<?xml version=”1.0″?>)? To my knowledge, xmldata is not a valid attribute. What are you trying to do?
Daniel.
November 6, 2009 at 12:19 PM in reply to: WCF Error when sending a string in multipart message #23678We changed our architecture away from a Biztalk implementation and this has been a long time ago. However, I recall reading that Biztalk’s WCF adapter has some limitations in regard to multi-part messages..
Hi Asri,
See the Microsoft article on the Walkthrough for Receiving EDI Interchanges:
http://msdn.microsoft.com/en-us/library/bb727695(BTS.20).aspx
Pay close attention to the section labeled “To create a party to receive the EDI interchange from“. You will find the information you need to configure your outbound acknowledgements properly there.
Daniel.
November 6, 2009 at 7:24 AM in reply to: WCF Error when sending a string in multipart message #23676Hi…did you manage to get to the problemof this issue?
Regards
Biztalker1
Well I have another issue now. The version number of the document in 997 comes out as 4000. The partner sends in a EDI304 with ISA/GS as follows
ISA*00* *00* *ZZ*ABCDEFG *ZZ*HIJKLMN *091104*0613*U*00400*000000743*0*T*>
GS*SO*ABCDEFG*HIJKLMN*20091104*0613*743*X*004010irrespective of my setup in EDI adapter of 997, my 997 comes out with version 4000.
ISA*00* *00* *ZZ*HIJKLMN *ZZ*ABCDEFG *091106*0803*U*00400*000010540*0*P*>
GS*FA*HIJKLMN*ABCDEFG*20091106*0803*10637*X*004000How can I fix this? Any help is highly appreciated.
Thanks, ASri
Ohhh, then I would not prolong this thread any more, I just wanted to be sure. Thanks.
November 5, 2009 at 3:47 PM in reply to: How to retrive Config Values from BizTalk Config File #23672Thanks for your valuable time Daniel….I have restrated Host Instance…I will get back to abount status.
November 5, 2009 at 3:18 PM in reply to: How to retrive Config Values from BizTalk Config File #23671Hi,
I checked the contents of your BTSNTSvc configuration file and nothing jumps out that would indicate something out of place. Did you restart your BizTalk application service after you made the changes? Another thing you can do is clean up your configuration file and remove any unnecessary tags/sections.
Daniel.
November 5, 2009 at 3:05 PM in reply to: How to retrive Config Values from BizTalk Config File #23670I removed </add> tag but still not able to get the value in orchestration..:(
-
AuthorPosts