    Or

    <Notes>
    <xsl:for-each select=”AdditionalInfo”>
      <xsl:value-of select=”concat(Description, ‘:’, Value” />
      <xsl:if test=”position() != last()”>
           <xsl:text>\n</xsl:text>
      </xsl:if>
    </xsl:for-each>
    </Notes>

    in reply to: Mapping problem – XML to String #23928

    You could try a scripting functoid with inline XSLT:

    <Notes>

    <xsl:for-each select=”AdditionalInfo”>

      <xsl:variable name=”var:v1″ select=”Description” /> 

      <xsl:variable name=”var:v2″ select=”Value” /> 

      <xsl:value-of select=”$var:v1″ /> 

      <xsl:value-of select=”$var:v2″ /> 

    </xsl:for-each>

    </Notes>

    in reply to: AS2 Connection #23927

    Hi,

     

       I suggest that you read the contents related to AS2 development in this publication:

     

    http://biztalkhotrod.com/Documents/BizTalk_HotRod_Issue6_Q2_2009.pdf

     

       This should give you ideas and guidelines on how to properly develop, configure and maintain a BizTalk application using AS2.

     

        Daniel.

     

    P.S.: as an observation and an advice to you, you should always do a search on the Biztalkgurus forums (or any other website, search engine and web resource, for that matter) to find out whether or not a certain question or topic has been answered already. This is a matter of doing due diligence and will significantly increase your productivity as a developer.

     

    in reply to: AS2 Tutorial #23924

    Daniel,

        it worked. I was using ASEDI Send instead of AS2 Send  on the send pipe of HTTP receive and so was giving me error. I changed to AS2 Send and it worked.

     

    Thanks  a lot for all the help

     

    Thank you

    Sangeetha

    in reply to: AS2 Tutorial #23923

    Have you checked the HTTP Adapter Properties and Schema?

     

    http://msdn.microsoft.com/en-us/library/aa547980(BTS.20).aspx

     

    Daniel.

     

    in reply to: AS2 Tutorial #23922

    Daniel,

        I got it work for the first half. I am getting the EDI messages, but now the MDNS are not getting created

     

    BTSHTTPReceive.dll” Reason: A message was encountered with root element name of Envelope. It could not be classified as an X12 or Edifact message. The root namespace was http://schemas.xmlsoap.org/soap/envelope/

     

    What could be the issue

     

    Thank you

    Sangeetha

     

    in reply to: SSO Problem #23921

    Hi,

     

       This could be a permissions issue. Check the following thread:

     

    http://www.tech-archive.net/Archive/BizTalk/microsoft.public.biztalk.general/2005-12/msg00416.html

     

       The user account doing the bindings import should also be a member of the group SSO Affiliate Administrators on that machine…

     

       Daniel.

     

    in reply to: AS2 Tutorial #23920

    Here are a couple of MSDN articles that should help you:

     

    http://support.microsoft.com/kb/894435

    http://msdn.microsoft.com/en-us/library/aa547969(BTS.20).aspx

     

    Daniel.

     

    in reply to: AS2 Tutorial #23919

    HI Daniel,

        I read that post since yesterday over and over again.

    Here are some more details.

    Biztalk is running on Bit 64 Windows 2003 server

    I checked the host instance and they are 32 bit.

    How can I,

    AS2 supports 64bit only in WOW mode, and in order to enable it you need to reference 32 bit version btshttpreceive.dll.

    How do I check this? is the webextensions or virtual directory or both?

    Also, you will need to make sure that IIS works in 32bit mode.

    How can I check this
     

    On top of that, 32 bit version of host instance will be needed, and 32 bit receive and send handlers for HTTP adapter are to be created and used.

    And how can I check this

     

    PLease help

     

    Thank you

    Sangeetha

     

    in reply to: AS2 Tutorial #23918

    Hi,

     

       Here’s a discussion on MSDN forum that should point you in the right direction:

     

    http://social.msdn.microsoft.com/Forums/en/biztalkediandas2/thread/9e489ec8-1d8a-4405-af20-f2266a16efb2

     

       Daniel.

     

    in reply to: Routing Binary Data #23917

    Hi,

     

      This could be due to the fact that you are using a FTP adapter on your Receive port, as there are known issues associated with the FTP adapter in BizTalk. Here is a snippet of documentation on how to troubleshoot and configure FTP adapter properly, hopefully that will help you:

     

    General Troubleshooting Questions and Answers

    This section contains a set of questions and answers designed to help you resolve issues with the FTP adapter.

    How do I enable logging?

    You can enable and configure logging by using the Log folder option in the FTP Transport Properties dialog box when configuring a receive location or send port with the FTP transport type.

    Depending upon your FTP server software, you may be able to configure logging for the FTP servers connected to by the BizTalk FTP adapter. Check the documentation for your server to assess your options.

    Why does the FTP adapter duplicate or lose data?

    If the FTP adapter retrieves a document from the FTP server that is still being written to by the host application, the retrieved document will be incomplete. If the FTP adapter retrieves an incomplete copy of the original document, data duplication or data loss may occur in the following scenarios:

      · If the original document is still being written to the FTP server by the host application, the FTP adapter cannot delete the document and will retrieve another copy of the document at the next polling interval that is configured for the receive location. This behavior causes document duplication to occur.

      · If the host application has finished writing the document to the FTP server, the document will be deleted. This behavior will cause data loss to occur.

    To avoid this behavior, use one of the following methods:

      · Configure the host application to write to a temporary folder on the same hard disk as the public FTP folder and to periodically move the contents of the temporary folder to the FTP folder. The temporary folder should be on the same hard disk as the public FTP folder to make sure that the move operation is atomic. An atomic operation is an operation that is functionally indivisible. If you write data to the public FTP folder by using the BizTalk Server 2006 FTP adapter, you can do this by specifying a Temporary Folder property in the FTP Transport Properties dialog box when you configure a send port.

      · Configure the FTP receive location to operate within a service window when the host application is not writing data to the FTP server. You can specify the service window when you configure the receive location properties.

    Common Errors

    You receive a “Failure occurred in parsing the remote folder listing” error message when you try to retrieve documents from or send documents to an FTP server

    Problem

    When you try to retrieve documents from or send documents to an FTP server by using the Microsoft BizTalk Server 2006 FTP adapter, you receive an error message that is similar to the following:

    A failure occurred in parsing the remote folder listing.

    Cause

    You may receive this error message if the following conditions are true:

      · The receive handler or the send handler for the BizTalk Server 2006 FTP adapter is configured to use a firewall mode of Passive.

      · The target FTP server does not permit passive connections.

    Resolution

    To resolve this behavior, use one of the following methods:

      · Configure the receive handler or the send handler, or both, for the BizTalk Server 2006 FTP adapter to use a firewall mode of Active.

      · Configure the target FTP server to permit passive connections.

    The FTP adapter can be used to connect to FTP servers on systems ranging from Solaris and Linux to AS/400. For more information about connecting to legacy systems, see Configuring an FTP Adapter to Work with Legacy Hosts.

    FTP receive adapter fails to publish message if receive pipeline processing time exceeds server time-out

    Problem

    A message received via the FTP adapter is not published to the MessageBox database. You may see errors similar to the following in the Application log for the BizTalk Server computer:

    Event Type:Error

    Event Source:BizTalk Server 2006

    Event Category:BizTalk Server 2006

    Event ID:5719

    Date:6/30/2006

    Time:12:08:55 PM

    User:N/A

    Computer:BIZTALKSERVER

    Description:

    There was a failure executing the receive pipeline: “Microsoft.BizTalk.DefaultPipelines.PassThruReceive, Microsoft.BizTalk.DefaultPipelines, Version=3.0.1.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35” Source: “Pipeline ” Receive Port: “ReceivePort1” URI: “ftp://FTPSERVER:21/*.txt&#8221; Reason: Unable to receive the file “file.txt   ” from the FTP server.

     

    and

    Event Type:Warning

    Event Source:BizTalk Server 2006

    Event Category:BizTalk Server 2006

    Event ID:5740

    Date:6/30/2006

    Time:12:08:56 PM

    User:N/A

    Computer:BIZTALKSERVER

    Description:

    The adapter “FTP” raised an error message. Details “Unable to receive the file “file.txt   ” from the FTP server. “.

    Cause

    The time taken to complete pipeline processing exceeds the FTP connection time-out.

    Resolution

    Use one of the following methods to mitigate this problem:

      · Increase the connection time-out value. Set the idle time-out value on the FTP server to be at least the amount of the time it takes to process the file.

      · Use the Temporary Folder feature on the receive location. In this case, the FTP adapter copies the file to the temporary folder (typically the local disk). It typically takes less time to copy the file to the local disk than to run the message through the pipeline and persist it to the MessageBox database, which effectively reduces the idle time.

    in reply to: Routing Binary Data #23915

    Yes, I’ve tried this. I’ve also tried using the BTS.ReceivePortID as a filter. Nothing seems to work. I’ve also made sure that the Send Handler associated with the FTP Adapter Target File Name is set to %MessageID%.zip

    I’m baffled.  

    in reply to: Routing Binary Data #23914

    Hi,

     

       In your Send Port, configure the Filters tab to select the property BTS.ReceivePortName and assign it the value of your Receive port, using the “==” operator. You are getting the error message because your send port is not subscribing to any message, so you want it to subscribe to your receive port in this case.

     

       Daniel.

     

    in reply to: Email via Biztalk #23912

    Hi,

     

       Yes, you can configure a physical Send Port in the BizTalk Administration Console to use a SMTP adapter to send emails. Here’s a blog that shows you how to do it:

     

    http://blogs.msdn.com/nabeelp/archive/2008/09/11/sending-an-html-email-without-an-orchestration.aspx

     

        Daniel.

     

    in reply to: Email via Biztalk #23911

    I was actually looking at using the SMTP functionality within Biztalk to read the table and send the email.  Since the C# application works presently, the benefit of calling it from Biztalk would not be much.  This is assuming I am understanding your reply correctly.