• Stephen W. Thomas
  • Azure Integration Gurus
BizTalkGurus
  • Home
  • Blogs
    • Stephen’s BizTalk and Integration Blog
    • BizTalk Community Blogs via Syndication
  • Forums
  • Downloads
  • Videos
  • Training
    • Online Training
    • Classroom Training
Select Page

HAT Connection Timeout on large Tracking Databases

by community-syndication | May 4, 2007 | BizTalk Community Blogs via Syndication

Recently while analysing a large (>15GB) tracking database on a BTS2004 install, my trusty friend HAT was coughing and spluttering – and moaning about timeouts.

Here’s how to increase the timeout value :

(from a MSDN arcticle)

  1. Click Start, click Run, type regedit,
    and then click OK.

  2. In Registry Editor, locate and then click the following
    subkey:

    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\BizTalk Server\3.0

  3. If there is a Tracking subkey, go to step 6.

  4. To create a Tracking subkey, on the Edit menu,
    point to New, and then click Key.

  5. Type Tracking, and then press ENTER.

  6. Locate and then click the following subkey:

    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\BizTalk Server\3.0\Tracking

  7. On the Edit menu, point to New, and then
    click DWORD Value.

  8. Type ConnectionTimeout, and then press ENTER.

  9. Right-click ConnectionTimeout, and then click Modify.

  10. In the Edit DWORD Value dialog box, click Decimal.

  11. In the Value data box, type the value in seconds
    that you want to set for the query timeout value, and then click OK.

  12. On the File menu, click Exit.

*** NOTE: the timeout value I’ve noticed only works with a value up to 30000. Any
higher causes this value to be igorned.
(From what I’ve noticed) ****

  • Facebook
  • Twitter
  • Google+
  • Gmail
  • LinkedIn

Search this Site:


Recent Posts

  • Logic App Consumption deployment: The secret of KeyVault parameter cannot be retrieved. Http status code: ‘Forbidden’. Error message: ‘Access denied to first party service
  • BizTalk Server Visual Studio project: attempted re-targeting of the project has been canceled.
  • BizTalk Oracle Adapter error: The assembly required for type mapping not found.
  • PowerShell script to identify all SQL V1 actions and triggers inside Logic Apps Consumption
  • Friday (funny) Fact: There is no size limit for the Logic App parameter name

Tweets by AzureIntGurus

Recent Topics

  • Evaluating on the amount of items returned in a message
  • Send and Receive ports problem
  • How to config/costom a WS Security to SOAP header
  • Email attachments – POP3 adapter
  • Calling ASP page from Biztalk Orchestration

  • Home
  • Blogs
  • Forums
  • Downloads
  • Videos
  • Training
  • Facebook
  • X
  • RSS
@BizTalkgurus.com