DFT DG1-3 – Switched from HL7 2.3 to 2.3.1 and now Pipeline complains on DG1-3 with Repeater "~"

Home Page Forums BizTalk 2004 – BizTalk 2010 DFT DG1-3 – Switched from HL7 2.3 to 2.3.1 and now Pipeline complains on DG1-3 with Repeater "~"

Viewing 0 reply threads
  • Author
    Posts
    • #26280

      We have been running on HL7 2.3 and just upgraded to 2.3.1 and now the DG1-3 part of the message is hanging in the pipeline if it has a repeater “~” element. Once I delete the Repeater and the extra Diag Codes it goes through. I have searched about every resource online and can not find an answer to this. PLEASE HELP, I’m pulling my hair out over this.

      Here is my Message:

      MSH|^~\&|ECW^RDC|RDC|GHA^RDC|RDC|20140221153500||DFT^P03|27|P|2.3.1
      EVN|P03|20140221153500
      PID|1|41007|42771|9121|TEST^TONY^||19650210|M|||1888 Any St^^Houston^TX^77046|0|1112223333|2817990413^|||||987654321
      PV1|1|O|^^^5901^TST – Rheumatic Disease Clinic of Houston||||1234567890^Willis^Sam,Multi^||||||||||||47|||||||||||||||||||||||||20140218113000||||||47||
      FT1|1|||20140218113000|20140221153500|CG|99215|||1.00||||||^^^5901^TST – Rheumatic Disease Clinic of Houston|||039.2~902.0~447.72~|1234567890^Willis^Sam,Multi^|1234567890||||99215|~~
      DG1|1||039.2~902.0~447.72~|||F|

       

      And here is the error:

      Error happened in body during parsing 
      Error # 1
      Segment Id: DG1_DiagnosisSegment
      Sequence Number: 1
      Field Number: 3
      Error Number: 102
      Error Description: Data type error
      Encoding System: HL7nnnn

Viewing 0 reply threads
  • The forum ‘BizTalk 2004 – BizTalk 2010’ is closed to new topics and replies.